BMRTY - DEVCHEM 253 WHITE BASE, 253B3210
- MSDS: BMRTY
- Manufacturer: DEVOE COATINGS CO
- Product Name: DEVCHEM 253 WHITE BASE, 253B3210
- National Stock Number: 8010-00N027049
Product Identification
Product ID:DEVCHEM 253 WHITE BASE, 253B3210
MSDS Date:08/17/1988
FSC:8010
NIIN:00N027049
MSDS Number: BMRTY
Responsible Party
LOUISVILLE, KY 40207
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 502-897-9861
Cage: 1HK86
Contractor
Telephone: 502-897-9861
Cage: 1HK86
Ingredients
BARIUM SULFATE
CAS: 7727-43-7
RTECS: CR0600000
Fraction By Weight: 15%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
4.0. LD50
CAS: 110-43-0
RTECS: MJ5075000
Fraction By Weight: 15%
OSHA PEL 100 PPM
ACGIH TLV: 50 PPM
5.9.
CAS: 71-36-3
RTECS: EO1400000
Fraction By Weight: <5%
OSHA PEL 100 PPM
ACGIH TLV: S, C 50 PPM; 9293
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
BY DELIBERATELY CONCENTRATING & INHALING
RTECS: 9999999ZZ
& NONSPARKING TOOLS. STORE IN CLOSED CONTAINER
RTECS: 9999999ZZ
CONVERTER PORTIONS WILL HAVE HAZARDS OF BOTH
RTECS: 9999999ZZ
THIS PRODUCT CONTAINS AN ING KNOWN TO THE STATE OF
RTECS: 9999999ZZ
HLTH STDS IN MIXING, APPLIC & CURING AREAS & TO
RTECS: 9999999ZZ
DURING WELDING & FLAME CUTTING ON SURFS COATED
RTECS: 9999999ZZ
REMOVING HEAVY SOLVENT VAPS FROM LOWER LVLS OF WORK
RTECS: 9999999ZZ
WHEN USED IN RESTRICTED VENT AREAS, WEAR
RTECS: 9999999ZZ
COMBINATION OF PARTICULATES & VAP. WHEN USED IN
RTECS: 9999999ZZ
OR USE HOODS. USE NIOSH/MSHA APPRVD RESP WHEN FLAME
RTECS: 9999999ZZ
WITH THIS PRODUCT.
RTECS: 9999999ZZ
EPOXY RESIN
Fraction By Weight: 40%
TALC (CONTAINING NO ASBESTOS); (SILICATE).
CAS: 14807-96-6
RTECS: WW2710000
Fraction By Weight: 10%
OSHA PEL 2 MG/M3 RDUST
ACGIH TLV: 2 MG/M3 RDUST
TITANIUM OXIDE; (TITANIUM DIOXIDE).
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 15%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
Hazards
LD50 LC50 Mixture:SEE INGREDIENT 5 & 6
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: IRRIT OF RESP TRACT,
HDCH, NAUS, DIZZ, WEAKNESS & FATIGUE. EXTREME EXPOS CAN RESULT IN
UNCON & EVEN RESP ARREST. SKIN/EYE: CAUSES EYE & SKIN IRRIT. MAY BE
HARMFUL IF ABSORBED THRU SKIN. INGEST: CAN CAUSE STOMACH
&/INTESTINAL IRRIT, NAUS, VOMIT & DIARRHEA. CHRONIC: REPORTS HAVE
ASSOC RPTD/(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: PRLNGD OCCUP OVEREXP TO SOLVS W/ PERM
BRAIN & CNS DMG. PRLNGD/RPTD BREATHING OF SPRAY MIST &/SANDING DUST
OVER A PERIOD OF YEARS MAY CAUSE DUST DISEASE OF THE LUNGS.
Medical Cond Aggravated by Exposure:NONE, WHEN USED I/A/W SAFE HANDLING
& USE INFORMATION.
First Aid
First Aid:INHAL: LEAVE AREA TO OBTAIN FRESH AIR. IF DFCLTY IS
EXPERIENCED, SUMMON MED ASSIST IMMED. IF BRTHG CEASES, RESTORE
USING APPRVD CPR TECHNIQUES & SUMMON MED HELP IMMED. EYES: FLUSH
IMMED W/ LGE AMTS OF WATER FOR AT LEAST 15 MINS. GET MED ASSIST.
SKIN: WASH AFFECTED AREAS W/SOAP & WATER. REMOVE SOILED CLTHG. GET
MED ASSIST IF IRRIT PERSISTS. INGEST: CONSULT MD IMMED. INTENTIONAL
MISUSE (ING 7)
Fire Fighting
Flash Point Method:SCC
Flash Point:100F,38C
Lower Limits:1%
Extinguishing Media:CO2, DRY CHEMICAL, FOAM OR OTHER NFPA APPRVD METHOD
FOR TREATING A CLASS B FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZ PREF. IF
EXPOS TO FIRE/EXTREME HEAT, (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELECT EQUIP, SPARKS & FLAME. DUE TO PRESS BUILDUP, CLSD
CNTNRS EXPOS TO EXTREME HEAT MAY EXPLO. NEVER (SUPP DATA)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT(FLAMES, HOT SURFS,
& ELECT, STATIC/FRICTIONAL SPARKS). PVNT BRTHG OF VAPS. VENT AREA.
BEFORE ATTEMPTING CLEANUP, REFER TO HAZ CAUTION INFO IN OTHER
SECTIONS OF MSDS. CONTAI N SPILLED MATL & REMOVE W/INERT ABSORB
(ING 8)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT/SPARKS/FLAMES. DO
NOT SMOKE. PVNT BUILDUP OF VAPS BY MAINT CONTINUOUS FLOW OF FRESH
AIR. DO NOT STORE >120F/NEAR FIRE/OPEN FLAME.
Other Precautions:STORE LGE QTYS IN BUILDINGS TO COMPLY W/OSHA
1910.106. KEEP CNTNR CLSD WHEN NOT IN USE. DO NOT TRANS CONTENTS TO
BOTTLES/OTHER UNLABELLED CNTNRS. DO NOT REUSE EMPTY CNTNRS. IF MATL
IS PART OF TWO COMP ONENTS, MIX OF BASE & (ING 9)
Exposure Controls
Respiratory Protection:DO NOT BREATHE VAPS, SPRAY MIST/SANDING DUST.
WHEN SPRAY APPLIED IN OUTDOOR OR OPEN AREAS, & DURING
SANDING/GRINDING OPERATIONS USE NIOSH/MSHA APPRVD MECH FILTER RESP
TO REMOVE SOLID AIRBORNE PARTICLE S OF OVERSPRAY & SANDING DUST.
(ING 14)
Ventilation:PROVIDE GENL DILUTION/LOC EXHST VENT IN VOL & PATTERN TO
KEEP AIR CONTAMINANT CONC BELOW CURRENT APPLIC SAFETY &(ING 11)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:DO NOT GET ON SKIN. SOLVENT IMPERMEABLE
CLOTHING AND BOOTS TO PREVENT SKIN CONTACT ARE RECOMMENDED.
Work Hygienic Practices:REMOVE AND WASH SOILED CLOTHING BEFORE REUSE.
WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
FIRE FIGHT PROC: WATER SHLD BE USED TO COOL CLSD CNTNRS & PVNT PRESS
BUILDUP/POSS AUTOIGNIT. EXPLO HAZ: USE A WELDING/ CUTTING TORCH
ON/NEAR CNTNR (EVEN EMPTY) AS PROD/ITS RESIDUE MAY IGNIT. DURING EM
ERG CNDTNS OVEREXP TO DECOMP PRODS MAY CAUSE A HLTH HAZ. SYMPS MAY
NOT BE IMMED APPARENT. OBTAIN MED ATTN.
Chemical Properties
HCC:F4
Boiling Pt:B.P. Text:244F,118C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:1.46
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:34
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY CAUSE TOXIC FUMES WHEN HEATED TO
DECOMPOSITION. FUMES MAY CONTAIN CO, CO2.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. INCINERATE ONLY IN APPROVED FACILTIY. DO NOT
INCINERATE CLOSED CNTNRS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.